DOT flash point testing evaluates the flammability characteristics of liquid products to support transportation classification under U.S. Department of Transportation (DOT) regulations.
Testing includes an initial closed-cup flash point determination using ASTM D93, followed by controlled evaporation for up to 4 hours or until 10% volume loss, whichever occurs first. A repeat flash point determination is performed when applicable under 49 CFR §173.120(c)(2).
The lower of the initial and post-evaporation flash point results is used for the applicable DOT evaluation.
Applications:
Test Method: ASTM D93 / 49 CFR §173.120(c)(2)
Reporting: A laboratory test report documenting the initial and post-evaporation flash point results, where applicable.
Note: Testing is subject to sample suitability for ASTM D93. Final transportation classification remains the responsibility of the shipper.